Introduction - If you have any usage issues, please Google them yourself
I used the single-chip 8952 and the voltage comparator 339 to do a simple capacitance measurement table, parameters are as follows: capacitance measurement range 1pF-9999.99uF, the minimum resolution for the 1pF. Divided into five ranges, you can automatically switch range can also be manually switched. In addition, a simple frequency meter function, capable of measuring 0-60MHz frequency digital signal (TTL level) can also lead to several single-point-frequency square-wave signal (for example, 1KHz). 1602LCD used as a monitor 4 button control use 24C01 to preserve the current settings, do not reset each boot. Can be a single 5V power supply, 9V AC power supply can also be